Kestrel 2500NV Weather Meter with Night Vision

$179.00

Nature can turn on you at a moment's notice. Predict what's headed your way with the perfect instrument for any outdoor activity.

Availability: In stock
SKU
0825NV




 FREE US SHIPPING

Kestrel 2500NV Weather Meter with Night Vision Overview


Environmental Measures
Altitude (Barometric)
Barometric Pressure
Temperature
Wind Chill
Wind Speed/Air Speed
Tips For Taking Accurate Measurements

The Kestrel 2500NV takes the great features of the Kestrel 2000 and adds in a pressure sensor.  Predict fish and wildlife activity as well as when bad weather is headed your way with the three-hour pressure trend indicator. With its easy-to-use digital pressure altimeter, you have the perfect instrument for any outdoor activity - get conditions in seconds right in the palm of your hand. In addition to predicting weather activity, barometric pressure also influences a bullet’s trajectory, which is why the Kestrel 2500NV is used by shooters and hunters when accuracy is important.


Note: The Kestrel 2500NV has a night-vision preserving backlight which helps users to sustain natural night vision. The NV's backlight incorporates an optical filter to reduce overall brightness and minimize blue and green spectrum light to preserve night vision. Additionally, NV backlights are also much dimmer than a standard backlight, making it more difficult to detect with the naked eye in night operations. This backlight appears soft greyish pink, not red, and is still in the visible spectrum, so it is not compatible with night-vision equipment.

It takes 30 to 45 minutes for the average eye to adapt to darkness and maximize night vision. Even a short burst of white, yellow, green or blue light “bleaches out” the rod cell photoreceptors in the eye and causes night blindness until the entire adaptation process can take place again. Light in the red spectrum does not cause this “bleaching out”, preventing night blindness and night vision fatigue.

Kestrel Weather & Environmental Meters are designed & manufactured in the U.S.A and are backed by our 5-year warranty. Innovatively designed for stability and accuracy in abrupt condition changes. Rugged and durable, Kestrels are drop tested, waterproof and designed to float if dropped in water.

Engraving Note: Please make sure that everything is spelled correctly, as your engraved product cannot be returned. All sales are final on engraved products. Add 2 business days to all engraving orders.

  • 3-Button Control
  • Backlight - Night Vision Preserving Light Red
  • Data Hold Function
  • Date & Time
  • Drop-Tested to MIL-STD-810G
  • Hard Slip-On Protective Cover
  • High Contrast, Sunlight Readable Monochrome LCD Display
  • Minimum/Maximum/Average Reading
  • Pressure Sensor
  • Temperature Sensor (Patented External Isolated)
  • Waterproof to IP67 (3'/1M for 30 minutes)
  • Battery - 1 x CR2032
  • Certificate Of Conformity (Spec Sheet)
  • Instructions
  • Lanyard
  • Protective Cover - Hard Slip-on
SENSORS
SENSORS 1
0
0
0
2
0
0
0
2
5
0
0
3
0
0
0
3
5
0
0
3
5
0
0
D
T
3
5
5
0
F
W
3
5
5
0
A
G
ACCURACY
(+/-)*
RESOLUTION SPEC. RANGE OP. RANGE NOTES
Wind Speed | Air Flow Larger of 3% of reading, least significant digit or 20 ft/min 0.1 m/s
1 ft/min
0.1 km/h
0.1 mph
0.1 knots
1 B*
0.1 F/S*
0.6 to 40.0 m/s
118 to 7,874 ft/min
2.2 to 144.0 km/h
1.3 to 89.5 mph
1.2 to 77.8 knots
0 to 12 B*
2-131.2 F/S*
0.6 to 60.0 m/s
118 to 11,811 ft/min
2.2 to 216.0 km/h
1.3 to 134.2 mph
1.2 to 116.6 knots
0 to 12 B*
2-196.9 F/S*
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min | 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. *F/S only in Ballistics units. Beaufort not available in Ballistics units.
Ambient Temperature 0.9 °F
0.5 °C
0.1 °F
0.1 °C
-20.0 to 158.0 °F
-29.0 to 70.0 °C
14.0.0 to 131.0 °F
-10.0 to 55.0 °C
Hermetically sealed, precision thermistor mounted externally and thermally isolated (US Patent 5,939,645) for rapid response. Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. Calibration drift negligible. Thermistor may also be used to measure temperature of water or snow by submerging thermistor portion into material -- remove impeller prior to taking submerged measurements and ensure humidity sensor membrane is free of liquid water prior to taking humidity-based measurements after submersion.
Relative Humidity 3.0 %RH 0.1 %RH 5 to 95%
non-condensing
0 to 100% Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074). To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift +/- 2% over 24 months. Humidity sensor may be recalibrated at factory or in field using Kestrel Humidity Calibration Kit (NK PN-0802).
Pressure 1.5hPa|mbar
0.044 inHg
0.022 PSI
0.1 hPa|mbar
0.01 inHg
0.01 PSI
25°C/ 77°F
750-1100 hPa|mbar
22.15-32.48 inHg
10.88-15.95 PS
0.30 to 48.87 inHg
10.0 to 1654.7
hPa|mbar
0.14 to 24.00 PSI
and
14.0 to 131.0 °F
-10.0 to 55.0 °C
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Pressure sensor may be recalibrated at factory or in field. Adjustable reference altitude allows display of station pressure or barometric pressure corrected to MSL. Kestrel 4200 displays station pressure on a dedicated screen. Kestrel 2500 and 3500 display continuously updating three-hour barometric pressure trend indicator: rising rapidly, rising, steady, falling, falling rapidly. Kestrel 4000 series displays pressure trend through graphing function. PSI display on Kestrel 4000 series only.
Compass
1/16th Cardinal
Scale
0 to 360° 0 to 360° 2-axis solid-state magnetoresistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit's vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power-down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout.
CALCULATED MEASUREMENTS
MEASUREMENT 1
0
0
0
2
0
0
0
2
5
0
0
3
0
0
0
3
5
0
0
3
5
0
0
D
T
3
5
5
0
F
W
3
5
5
0
A
G
ACCURACY
(+/-)*
RESOLUTION SPEC. RANGE SENSORS EMPLOYED NOTES
Altitude typical:
23.6ft/7.2m
max:
48.2ft/14.7m
1ft
1m
typical:
750 to 1100 mBar
max:
300 to 750 mBar
Pressure User Input (Reference Pressure) Height above Mean Sea Level ("MSL"). Temperature compensated pressure (barometric) altimeter requires accurate reference barometric pressure to produce maximum absolute accuracy. Both accuracy specs corresponds to a reference pressure anywhere from 850 to 1100 mBar.
Barometric Pressure 0.07 inHg
2.4 hPa|mbar
0.01 inHg
0.1 hPa|mbar
Refer to Ranges for Sensors Employed Pressure User Input (Reference Altitude) Air pressure that would be present in identical conditions at MSL. Station pressure compensated for local elevation provided by reference altitude. Requires accurate reference altitude to produce maximum absolute accuracy
Delta T 3.2 °F
1.8 °C
0.1 °F
0.1 °C
Refer to Ranges for Sensors Employed Temperature
Relative Humidity
Pressure
Difference between dry bulb temperature and wet bulb temperature. When spraying, indicates evaporation rate and droplet lifetime. Safe range for pesticide spraying is 4 to 16 °F / 2 to 9 °C.
Dew Point 3.4 °F
1.9 °C
0.1 °F
0.1 °C
15 to 95 % RH
Refer to Range for Temperature Sensor
Temperature Relative Humidity Temperature that a volume of air must be cooled to at constant pressure for the water vapor present to condense into dew and form on a solid surface. Can also be considered to be the water-to-air saturation temperature.
Heat Index 7.1°F
4.0°C
0.1 °F
0.1 °C
Refer to Ranges for Sensors Employed Temperature Relative Humidity Perceived temperature resulting from the combined effect of temperature and relative humidity. Calculated based on NWS Heat Index (HI) tables. Measurement range limited by extent of published tables
Temperature Humidity Index - THI (NRC) 1.5°F
0.8°C
0.1 °F
0.1 °C
Refer to Ranges for Sensors Employed Temperature Relative Humidity
Temperature Humidity Index - THI (Yousef) 2.3°F
1.3°C
0.1 °F
0.1 °C
Refer to Ranges for Sensors Employed Temperature Relative Humidity
Wet Bulb Temperature - Psychrometric 1.6 °F
0.9 °C
0.1 °F
0.1 °C
Refer to Ranges for Sensors Employed Temperature
Relative Humidity
Pressure
Temperature indicated by a sling psychrometer. Due to nature of the psychrometric ratio for a water-air system, this approximates the thermodynamic wet-bulb temperature. The thermodynamic wet-bulb temperature is the temperature a parcel of air would have if cooled adiabatically to saturation temperature via water evaporating into it.
Wind Chill 1.6 °F
0.9 °C
0.1 °F
0.1 °C
Refer to Ranges for Sensors Employed Wind Speed
Temperature
Perceived temperature resulting from combined effect of wind speed and temperature. Calculated based on the NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at 10m above ground. Measurement range limited by extent of published tables.
ADDITIONAL SPECIFICATIONS
MEASUREMENT 1
0
0
0
2
0
0
0
2
5
0
0
3
0
0
0
3
5
0
0
3
5
0
0
D
T
3
5
5
0
F
W
3
5
5
0
A
G
NOTES
Display & Backlight Reflective 3 1/2 digit LCD. Digit height 0.36 in / 9 mm. Aviation green electroluminescent backlight. Manual activation with auto-off
Reflective 5 digit LCD. Digit height 0.36 in / 9 mm. Choice of aviation green or visible red (NV models only) electroluminescent backlight. Manual activation with auto-off.
Response Time & Display Update All measurements except those based on relative humidity respond accurately within 1 second. Relative humidity and all measurements which include RH in their calculation may require as long as 1 minute to fully equilibrate to a large change in the measurement environment. Display updates every 1 second.
Max/Avg Wind One-button clear and restart of Max Wind Gust and Average Wind measurement.
Data Upload & Bluetooth® Data Connect Option Requires optional PC interface (USB or RS-232) or Bluetooth data transfer option and provided software.
Bluetooth Data Transfer Option: Adjustable power consumption and radio range from up to 30 ft | 9 meters. Individual unit ID and 4-digit PIN code preprogrammed for easy identification and data security when pairing and transmitting. Employs Bluetooth Serial Port Protocol for data transmission.
Clock / Calendar Real-time hours:minutes clock.
Auto Shutdown After 45 minutes of no key presses.
Languages English
Certifications CE certified, RoHS and WEEE compliant. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge).
Origin Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery Life CR2032, one, included. Average life, 300 hours. Battery life reduced by backlight use in 2000 to 3500 models.
Shock Resistance MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
Sealing Waterproof (IP67 and NEMA-6).
Operational Temperature Limits 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and exposing it to the more extreme environment for the minimum time necessary to take reading.
Storage Temperature -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
Size & Weight 4.8 x 1.9 x 1.1 in / 12.2 x 4.8 x 2.8 cm, 3.6 oz / 102 g (including slip-on cover).

* NOTE: Accuracy calculated as uncertainty of the measurement derived from statistical analysis considering the combined effects from primary sensor specifications, circuit conversions, and all other sources of error using a coverage factor of k=2, or two standard deviations (2Σ).

Kestrel Basic (1000-3500) Certificates of Comformity

Certificate of Conformity for the Kestrel 1000-3500DT with SNs above 2262687



Kestrel Basic (1000-3500) Certificates of Comformity

Certificate of Conformity for the Kestrel 1000-3500DT with SNs above 2262687

EMC DECLARATION OF CONFORMITY 2500, 2500NV, 3500, 3500NV

Kestrel 5 Series Troubleshooting Documents

Here is guidance on how to submit an order through the website for Tax Exempt customers.

Support Documents for all Kestrels

Product Safety and Warranty Kestrel 5000 Series

Kestrel Basic (1000-3500) Instruction Manuals

User Guide for the Kestrel 1000 , 2000 , 2500 & 2500 NV , 3000 , 3500 & 3500 NV , 3500 DT

Visit our support page for FAQ and more.

  1. Improve Your Fishing Strategy with Kestrel 2500 Pocket Weather Meter Whether you enjoy fishing for stress relief or you’re a seasoned pro, the Kestrel 2500 pocket weather meter can help improve your overall fishing strategy. While baiting a hook with a worm and casting it into the water is a simple approach, the Kestrel 2500 can take your fishing game to the next level.
Other Items you Might Consider
Accessories