Fire Weather Chief Pro Kit

$779.00

The Fire Chief Pro Kit contains two (2) Kestrel 5500FW Fire Weather Meters Pro with LiNK and one (1) DROP D3FW Datalogger!

Works with AWN, the Ambient Weather Network
Availability: In stock
SKU
0855L0730PPFW




 FREE US SHIPPING

Fire Weather Chief Pro Kit Overview


Fire Chief Pro Kit contains two (2) Kestrel 5500FW Fire Weather Meters Pro with LiNK and one (1) DROP D3FW Datalogger. The 5500FW meter is an all-in-one hand-held belt weather kit replacement, containing every critical weather measurement including PIG and FDFM. The DROP D3FW data logger can be left onsite for continuous recording of conditions and trends which can then be viewed on a mobile device and shared via email. Measure, log, track trends and expand capabilities with this kit on the free Kestrel LiNK App.


Kestrel 5500FW Fire Weather Meter Pro with LiNK

Kestrel 5500FW Fire Weather Meter Pro with LiNK

The fast and easy tool for taking weather observations, the Kestrel 5500FW Fire Weather Meter Pro provides NIST-traceable accuracy, reliability and usability when it matters most. Measure every environmental condition plus PIG and FDFM and view trends with on-screen data graphing. Drop-proof, dust-proof, waterproof and able to withstand extreme environments without damage, your Kestrel Fire Weather meter can stand up to the abuses of work on a fire line wherever you’re assigned. Measures wind speed (anemometer) and direction, temperature (thermometer), humidity (hygrometer), water vapor content of the atmosphere (psychrometer), plus 10 other meterological paramenter.

Read more about the Kestrel 5500FW Fire Weather Meter Pro with LiNK


Kestrel DROP D3FW Datalogger

Kestrel DROP D3FW

Each Kestrel Fire Weather DROP measures just 1 x 1.8 x 2.4 inches (24 x 46 mm x 60 mm) and weighs just 1.2 ounces (34 grams). DROP loggers meet military and international standards for water, dust and shock resistance (IP-67 and MIL-STD-810G) and are conveniently equipped with a sturdy D-ring for hanging wherever needed. The DROP D3FW measures: Dew Point Temperature, Heat Stress Index, Pressure Trend, Relative Humidity, Station Pressure (Absolute Pressure), Temperature, Wet Bulb Temperature.

Read more about the Kestrel DROP D3FW Datalogger

  • Backlight - Switchable White/Red
  • Battery Life Indicator
  • Data Log Graph View
  • Data Logging - Adjustable Interval
  • Date & Time
  • Digital Compass
  • Drop-Tested to MIL-STD-810G
  • Integrated Flip Open Impeller Cover
  • Intuitive Tactile Up/Down/Enter Keypad
  • LiNK Wireless Communication to Mobile Devices (Bluetooth low energy)*
  • Multilingual Menus (English, French, Spanish, German)
  • Pressure Sensor
  • Relative Humidity Sensor
  • Temperature Sensor (Patented External Isolated)
  • Waterproof to IP67 (3'/1M for 30 minutes)

* Applies to LiNK models only

  • Battery - 1 x AA
  • Certificate Of Conformity (Spec Sheet)
  • Instructions
  • Lanyard
  • Protective Drawstring Pouch

The specs on this page relate to all Kestrel 5 series meters. Just because a measurement is listed in this chart does not necessarily mean that it is included with all meters. To see a listing of all measurements and features for this meter, please click on the In-Depth tab above.

SENSORS
SENSORS ACCURACY RESOLUTION SPECIFICATION RANGE NOTES
Wind Speed | Air Speed Larger of 3% of reading, least significant digit or 20 ft/min Speed 0.1 m/s
1 ft/min
0.1 km/h
0.1 mph
0.1 knots
1 B*
0.1 F/S*
0.6 to 40.0 m/s
118 to 7,874 ft/min
2.2 to 144.0 km/h
1.3 to 89.5 mph
1.2 to 77.8 knots
0 to 12 B*
2-131.2*
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH|7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller
Ambient Temperature 0.9 °F
0.5 °C
0.1 °F
0.1 °C
-20.0 to 158.0 °F
-29.0 to 70.0 °C
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits.
Relative Humidity 2%RH 0.1 %RH 10 to 90% 25°C noncondensing To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year.
Pressure 1.5 hPa|mbar
0.044 inHg
0.022 PSI
0.1 hPa|mbar
0.01 inHg
0.01 PSI
25°C/77°F
700-1100 hPa|mbar
20.67-32.48 inHg
10.15-15.95 PSI
Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product.
Compass
1/16th Cardinal Scale
0 to 360° 2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout.

CALCULATED MEASUREMENTS
MEASUREMENT ACCURACY (+/-) RESOLUTION SENSORS EMPLOYED
Air Density 0.0002 lb/ft3
0.0033 kg/m
0.001 lbs/ft3
0.001 kg/m3
Temperature, Relative Humidity Pressure
Air Flow 6.71% 1 cfm
1 m3/hr
1 m3/m
0.1m3/s
1 L/s
Air Speed, User Input (Duct Shape & Size)
Altitude typical: 23.6 ft/7.2 m
from 750 to 1100 mBar
max: 48.2 ft/14.7 m
from 300 to 750 mBar
1 ft 1 m Pressure, User Input (Reference Pressure)
Barometric Pressure 0.07 inHg
2.4 hPa|mbar
0.03 PSI
0.01 inHg
0.1 hPa|mbar
0.01 PSI
Pressure, User Input (Reference Altitude)
Crosswind & Headwind/Tailwind 7.1% 1 mph
1 ft/min
0.1 km/h
0.1 m/s
0.1 knots
Wind Speed, Compass
Delta T 3.2 °F
1.8 °C
0.1 °F 0.1 °C Temperature, Relative Humidity Pressure
Density Altitude 226 ft
69 m
1 ft 1 m Temperature, Relative Humidity Pressure
Dew Point 3.4 °F
1.9 °C
15-
95% RH. Refer to Range for Temperature Sensor
0.1 °F
0.1 °C
Temperature, Relative Humidity
Evaporation Rate 0.01 lb/ft2/hr
0.06 kg/m2/hr
0.01 b/ft2/hr
0.01 kg/m2/hr
Wind Speed, Temperature Relative Humidity Pressure, User Input (Concrete Temperature)
Heat Index 7.1°F
4.0°C
0.1 °F
0.1 °C
Temperature, Relative Humidity
Moisture Content | Humidity Ratio (“Grains”) 4.9gpp
.7g/kg
0.1 gpp
0.01 g/kg
Temperature, Relative Humidity Pressure
Probability of Ignition (PIG) PIG Accuracy dependent on proximity of inputs to reference table steps. 10% Temperature, Relative Humidity
THI (NRC) 1.5 °F
0.8 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity
THI (Yousef) 2.3 °F
1.3 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity
Relative Air Density .0.3% 0.1% Temperature, Relative Humidity Pressure
Wet Bulb Temperature - Psychrometric 3.2 °F
1.8 °C
0.1 °F
0.1 °C
Temperature, Relative Humidity Pressure
Wet Bulb Temperature - Naturally Aspirated (NWB TEMP) 1.4 °F
0.8 °C
0.1 °F
0.1 °C
Wind Speed, Temperature Globe Temperature, Relative Humidity, Pressure
Wind Chill 1.6 °F
0.9 °C
0.1 °F
0.1 °C
Wind Speed, Temperature
 
ADDITIONAL PRODUCT INFO
Display & Backlight Multifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight.
Response Time & Display Update Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes.
Data Storage & Graphical display Min/Max/Avg History Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points.
data Upload & Bluetooth Data Connect Option Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC).
Clock/Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Auto Shutdown User-selectable – Off, 15-60 minutes with no key presses.
Languages English, French, German, Spanish.
Certifications CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards.
Origin Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B.
Battery Life AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use.
Shock Resistance MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller.
Sealing Waterproof (IP67 and NEMA-6)
Display & Battery Operational Temperature Limits 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading.
Storage Temperature -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C.
Size & Weight 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included)

Kestrel 5 Series Certificates of Comformity

Kestrel 5 Series specification chart




Visit our support page for FAQ and more.